Point of Product
Features and Benefits
No capital equipment required |
Connection is made in seconds |
Connector can be autoclaved or Gamma sterilized |
Easy to make connection – even in cramped environment |
Maintains a sterile fluid pathway upon activation of device |
Peel-away strip maintains sterility until ready to use |
Vented to allow steam penetration and to prevent tubing collapse after autoclaving |
Shape coding ensures proper alignment |
Locking mechanism prevents incorrect assembly |
Device makes audible click when engaged |
Permanent connection for security – cannot be re-opened |
Quality Standards
Manufactured under clean conditions in a controlled environment |
Manufactured under a Quality Management System certified to ISO 9001 |
Supplied with a Certificate of Test confirming the quality standards and quality control tests performed by Pall (including endotoxin USP<85> and particulate tests) |
Validation Tests Include: - Burst - Creep-rupture - Aerosol Challenge - Shelf-Life - Absence of BPA (Bisphenol-A) - Bacterial spore challenge ('soiling') test - Closure integrity - Water flow characteristics - Extractables Autoclave |
The Fluid Path Materials of Construction Meet: - Biological Reactivity Tests in vivo for Class VI-121°C Plastics, USP <88> - USP Physicochemical Tests for plastics, USP<661> |
Specification
Materials of Construction
Aqueous Extractables (NVR)
Sterilization Methods
Operating Conditions
Connections (Male and Female)
Nominal Dimensions
Component
|
Material of Construction |
Connector body |
Polycarbonate |
Plunger |
Polycarbonate |
Rubber grommets |
Thermoplastic elastomer |
O ring |
Internally lubricated ethylene propylene |
Adapters |
Polycarbonate with TiO2 |
Protective cap |
Polypropylene |
Peel-away strip |
Hydrophobic polyethersulfone |
Anti-actuation ring |
Thermoplastic elastomer |
Aqueous Extractables (NVR) | Value |
Water at 20 - 25°C after autoclaving at 130°C | Typically <1 mg |
Sterilization Method
|
Guidance |
Gamma irradiation |
50 kGy |
Autoclave |
75 minutes at 130°C |
Parameter
|
Value
|
Maximum operating pressure and temperature |
3 bar at 40°C |
Sizes |
6 mm (1/4 in.) hose barb |
9.6 mm (3/8 in.) hose barb |
13 mm (1/2 in.) hose barb |
15.8 mm (3/8 in.) hose barb |
|
6 mm (1/4 in) Hose Barb |
9.6 (1/4 in) Hose Barb |
13 mm (1/2 in) Hose Barb |
15.8 mm (5/8 in) Hose Barb |
Male | KPCH T02M7 | KPCHT02M10 | KPCHT02M6 | KPCHT02M11 |
Female | KPCHT02F7 |
KPCHT02F10 |
KPCHT02F6 |
KPCHT02F11 |
Internal diameter | 5.5 mm (0.22 in.) | 8.2 mm (0.32 in.) | 12.2 mm (0.48 in.) | 13.8 mm (0.54 in.) |
Length when actuated | 173 mm (6.8 in.) | 173 mm (6.8 in.) | 123 mm (4.8 in.) | 13.8 mm (0.54 in.) |
Female connector length with cap | 80 mm (3.2 in.) | 80 mm (3.2 in.) | 55 mm (217 in.) | 83 mm (3.27 in.) |
Maximum diameter of female connector | 38 mm (1.48 in.) | 38 mm (1.48 in.) | 38 mm (1.48 in.) |
38 mm (1.48 in.) |
Male connector length with cap | 125 mm (4.92 in.) | 125 mm (4.92 in.) | 100 mm (3.94 in.) | 128 mm (5.04 in.) |
Maximum diameter of male connector | 38 mm (1.48 in.) | 38 mm (1.48 in.) | 38 mm (1.48 in.) | 38 mm (1.48 in.) |
Specifications and avaibility. The information provided is a guide to the part number structure and possible options. Product avaibility may be subject to change without notice. All specifications are nominal.
Warning: This product is not sold sterelie. For use in making sterelie connections. each connector must tbe fitted to a closed single-use assembly that has been subjected to a validated sterilizing process
Warning: This product is not sold sterelie. For use in making sterelie connections. each connector must tbe fitted to a closed single-use assembly that has been subjected to a validated sterilizing process
Applications
-
Transfer of inoculums to reactors
-
Sampling during fermentation or cell culture
-
Connection of small sterile equipment to large equipment (e.g., bioreactors)
-
Handling of bulk material in a nonsterile environment
-
Connection from tank to filling line
-
Connection to a disposable system
-
Sensor insertion into bioreactor
-
Connectors and Disconnectors