Nylon N66 Filter
Pall Ultipor® N66 sterilizing-grade filter cartridges feature high-strength pure Nylon 6,6 membranes for higher sterility assurance. In wide use for almost 20 years, these filters have a proven record of performance in the production of sterile biologicals and pharmaceuticals. High-area pleated into single open-ended (SOE) AB sanitary style cartridges, Ultipor N66 sterilizing-grade filter cartridges are available with ratings from 0.45 µm for LVPs, reagents and viscous fluids, 0.2 µm for sterile products and intermediates, 0.1 µm for sterilization and mycoplasma removal from biologicals, to 0.04 µm for sterilization and virus reduction from biologicals.
Point of Product
Specification
Membranes
|
Nylon 6,6, double-layer
|
Support. Drainage and End Caps
|
Polyester
|
Core and Cage
|
Polypropylene
|
O-rings
|
Silicone
1
|
NR, NF
|
0.2 µm sterilizing-grade
|
NT
|
0.1 µm mycoplasma sterilizing-grade
|
Lengths
|
254 mm (10 in.), 508 mm (20 in.), 762 mm (30 in.), 1016 mm (40 in.)
|
Diameter
|
70 mm (2.75 in.)
|
Maximum Differential Pressure during Steam-Sterilization
|
300 mbar (4.35 psi) in a forward direction
|
Maximum Differential Pressure and Temperature
|
5.5 bard (80 psid) to 50 °C 4.1 bard (60 psid) to 80 °C |
Configuration (AB Code 7)
Double 226 O-ring adapter Fin end with bayonet lock |
Autoclavable or Steamable In-situ
Cumulative Steam Exposure
|
16 hours (1-hour cycles) at 121 °C 4 hours (1-hour cycles) at 140 °C |
Aqueous Extractables (NVR) per 254mm (10 in.) Element
Typically 15 – 25 mg
|
Type
Filter Cartridges
Ordering Information
AB |
SIZE |
Type |
Forward Flow |
Grade |
Gasket |
|||||
Code |
Nominal Length |
Code |
Removal Rating |
Area |
- |
Code |
Filter Grade |
Code |
Gasket Option |
|
|
05 |
5 in.
|
NF |
0 .2 μm |
0.79
m2 |
12 at 2760 (40) |
P |
Pharmaceutical* |
H4 |
Silicone |
|
1 |
10 in.
|
NR |
0.2 μm |
0.46 m2 |
8 at 2760 (40) |
Omit |
General Use |
|
|
|
2 |
20 in.
|
NT |
0.1 μm |
0.79 m2 |
14 at 5175 (75) |
|
|
||
|
3 |
30 in.
|
|
|
|
|
||||
|
4 |
40 in.
|
|